| Project Overview |
| Project Name: |
ISCC Ain Beni Mathar |
| Country: |
Morocco |
| Location: |
Ain Beni Mathar (Ain Beni Mathar) |
| Owner(s): |
ONE (Office National de l'Electricite)
(100%)
|
| Technology: |
Parabolic trough |
| Turbine Capacity: |
Net: 20.0 MW
Gross: 20.0 MW |
| Status: |
Operational |
| Start Year: |
2010
|
Do you have more information, corrections, or comments?
ISCC Ain Beni Mathar
This page provides information on ISCC Morocco, a concentrating solar power (CSP) project, with data organized by background, participants, and power plant configuration. Integrated Solar Combined-Cycle (ISCC) technology combines the benefits of solar energy with the benefits of a combined cycle. The solar resource partially substitutes the fossil fuel. The project consist of a 470 MWe hybrid power plant composed of a combined cycle and a 20 MWe solar thermal system.
| Status Date: |
January 24, 2013
|
Background
| Technology: |
Parabolic trough |
| Status: |
Operational |
| Country: |
Morocco |
| City: |
Ain Beni Mathar |
| Region: |
Ain Beni Mathar |
| Lat/Long Location: |
34°3′
50.0″
North,
2°6′
0.0″
West |
| Electricity Generation: |
55,000 MWh/yr
|
| Contact(s): |
Mª José Mosquera |
| Company: |
Abener |
| Break Ground: |
April 2008 |
| Start Production: |
May 2010 |
| PPA/Tariff Period: |
25 years
|
| Project Type: |
Commercial |
Participants
| Developer(s): |
Abener |
| Owner(s) (%): |
ONE (Office National de l'Electricite)
(100%)
|
| EPC Contractor: |
Abener |
| Operator(s): |
Abengoa Solar / ONE |
| Generation Offtaker(s): |
ONE (Office National de l'Electricite) |
Plant Configuration
Solar Field
| Solar-Field Aperture Area: |
183,120 m² |
| # of Solar Collector Assemblies (SCAs): |
224 |
| # of Loops: |
56 |
| # of SCAs per Loop: |
4 |
| SCA Length: |
150 m |
| SCA Manufacturer (Model): |
Abengoa Solar
(ASTR-Ø)
|
| Mirror Manufacturer: |
Rioglass |
| # of Heat Collector Elements (HCEs): |
8,064 |
|
HCE Manufacturer (Model): |
Schott (PTR70) |
| Heat-Transfer Fluid Type: |
Therminol VP-1 |
| Solar-Field Outlet Temp: |
393°C |
Power Block
| Turbine Capacity (Gross): |
20.0 MW
|
| Turbine Capacity (Net): |
20.0 MW |
| Output Type: |
Steam Rankine |
| Cooling Method: |
Wet cooling |
Thermal Storage