Fiscal Year 2021 Quarterly Allocation Reductions
March 3, 2021
You may have noticed that NREL did not make any reductions to allocations that were
under-using their AUs during Q1. This is for two reasons. First, we were in the
process of putting together a new, more transparent, fairer allocation reduction policy.
Second, we are aware that many users were inconvenienced by the fact that allocation
decisions were issued on October 1.
We realize allocation reductions for low use are not popular with our users. However,
they are physically necessary. AUs are an “expiring resource.” If an AU is not
used in Q1, it cannot be stored and saved for use in Q4. Because of this, we have
to remove some percentage of the unused AUs every quarter. Otherwise we can hit a
situation where we have many more AUs available to users than the machine can physically
provide as the year progresses. This creates long queue times that make Eagle physically
unusable.
Our new allocation policy is given below. We had an informal discussion with users
across multiple centers before designing this policy. Users emphasized the need for
a policy to be clear enough so they could see what they might lose at the end of the
quarter. Users have also increasingly requested allocations that had different usages
in different quarters to deal with their project needs, and we wanted a policy that
treated these fairly.
Shortly after Q1, Q2, and Q3 ends, allocations will be automatically adjusted to
account for low utilization against planned usage. At the end of each quarter, the
total allocation units used for the year to date will be compared to the total planned
usage for the year to date for each allocation. At the end of Q1, the total used
for the year to date is compared to the Q1 planned usage; at the end of Q2, the total
used for the year to date is compared to the Q1+Q2 planned usage, and at the end of
Q3, the toal used for the year to date is compared to the Q1+Q2+Q3 planned usage.
Allocation units are then removed based on the table below. Note that allocation
reductions are meant to be cumulative over the course of a year, and not compounding.
If, for instance, a project was reduced by 10,000 AUs for low usage in Q1, and the
reduction table suggests the project should be reduced by 25,000 AUs at the end of
Q2, 15,000 (25,000-15,000) AUs should be removed at the end of Q2 to make the total
removal for the year to date equal to 25,000 AUs.
Percentage of planned AUs used to date | Percentage of planned to date AUs removed |
---|---|
More than 70% | 0% (No reduction) |
Less than 70% but greater than 55% | 20% |
Less than 55% but greater than 40% | 35% |
Less than 40% but greater than 20% | 55% |
Less than 20% | 80% |
To understand how this process would work, we consider the following two 100,000 AU allocations, one with a uniform distribution of planned AUs throughout the year, and one with a distribution designed to enable development in Q1 and production runs in Q2 through Q4. The two allocations are described in the table below.
Quarter | Allocation "Renewables" | Allocation "Efficiency" |
---|---|---|
Q1 | 25,000 | 10,000 |
Q2 | 25,000 | 30,000 |
Q3 | 25,000 | 30,000 |
Q4 | 25,000 | 30,000 |
To understand how this process would work, we consider the following two 100,000 AU allocations, one with a
If “Renewables” uses 9,000 AUs in Q1, 20,000 AUs in Q2, and 25,000 AUs in Q3, it would
be reduced in the following manner:
After Q1, the project will have used 36% (9,000/25,000) if its allocation, leading
to 13,750 (55% x 25,000) AUs being removed.
After Q2, the project will have used 58% [(9,000+20,000)/(25,000+25,000)] of its
allocation, leading to 10,000 AUs (20% x 50,000) being potentially removed. However,
because 12,500 AUs were removed in Q1, no removal is performed. Note that AUs are
not restored in this case.
After Q3, the project will have used 72 % [(9,000+20,000+25,000)/(25,000+25,000+25,000)]
of its allocation. No reduction would be made. The project would then begin Q4 with 33,500
AUs (100,000-9,000-20,000-25,000-12,500).
If “Efficiency” uses AUs under the same schedule, after Q1, the project will have
used 90% (9,000/10,000) of its allocation and will not be penalized.
After Q2, the project will have used 72.5% [(9,000+20,000)/(10,000+30,000)] of its
allocation and will not be penalized.
After Q3, the project will have used 77% [(9,000+20,000+25,000)/(10,000+30,000+30,000)]
of its allocation, and will not be penalized. The project would then begin Q4 with
46,000 AUs.
Note that “Renewables” and “Efficiency” have the same total (100,000 AUs) but lose
very different amounts of AUs over the course of the year. This is because the allocation
request “Efficiency” is more closely tuned to the user’s actual us of HPC resources.
NREL allows users to tune their allocation request through the use of “profiles” in
the allocation request to avoid this sorts of reductions.
This information can also be found by visiting the Fiscal Year 2021 Quarterly Allocation Reductions page on our website.