Skip to content National Residential Efficiency Measures Database National Renewable Energy Laboratory

Submit Questions/Comments

Retrofit Measures for Windows

Here you will find the data for Windows measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Windows measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Windows measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Access
  • Existing construction and materials
  • Moisture issues present
  • Presence of hazardous materials
  • Extent of preparation

Viewing 516 Windows Measure(s) of 516

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4233

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4233

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4233

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Add Storm Sash:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 7.2 - 1411

Add Window Film:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 5.7 - 108.1

Add Storm Sash:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 13 - 2319

Add Window Film:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 2.1 - 3.93.1

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Metal w Thermal Break Frame, Air Fill

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4133

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Clear, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Add Storm Sash:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 7.2 - 1411

Add Window Film:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Non-metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.35
  • Storm Sash:
  • U-Value: 0.78 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 5.7 - 108.1

Add Storm Sash:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Non-metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.475
  • Storm Sash: low-e
  • U-Value: 0.395 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 13 - 2319

Add Window Film:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Non-metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.82 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 2.1 - 3.93.1

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5140

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 54 - 9778

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 75 - 130110

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern, South-Central, Southern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5342

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 24 - 4636

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 26 - 4939

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 30 - 5745

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 23 - 4535

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 25 - 4838

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 28 - 5443

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4334

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Double-Pane, Medium-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 22 - 4435

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Air Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 46 - 8367

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window 61 - 11088

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Triple-Pane, High-Gain Low-E, Non-metal Frame, Air Fill

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years