MIDC/Data Quality Statements
Total Records: 27, displaying 1-25
[Next Records]
R#SiteSerial NumberMeasurementStart DateStart TimeEnd DateEnd TimeData Quality Statement
1BMSGlobal TSP-70012/28/201306:46:0012/28/201315:59:00Due to a scheduled NREL power outage, to upgrade campus electrical infrastructure, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, TSI-880, PGS-100, POM-01, TWC, EFM-100.
2BMSGlobal TSP-70012/21/201307:00:0012/21/201316:22:00Due to a scheduled NREL power outage, to upgrade campus electrical infrastructure, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, TSI-880, PGS-100, POM-01, TWC, EFM-100.
3BMSGlobal TSP-70003/02/201308:06:0003/02/201318:24:00Due to a scheduled NREL power outage, to upgrade campus power capacity, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, TSI-880, PGS-100, POM-01, TWC, EFM-100.
4BMSGlobal TSP-70005/26/201206:15:0005/26/201207:12:00Due to a planned power outage for SRRL electrical work, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, PGS-100, POM-01, TWC.
5BMSGlobal TSP-70011/12/201111:59:0011/12/201113:26:00Due to an undervoltage followed by a power outage at 13:12, the following BMS instruments may be reading bogus or invalid data: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, TWC.
6BMSGlobal TSP-70009/08/201105:56:0009/08/201109:19:00Due to a planned power outage for SRRL construction activities, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, PGS-100, POM-01, TWC.
7BMSGlobal TSP-70006/14/201113:01:0006/14/201113:14:00Due to a planned power outage for SRRL construction activities, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, TSI-880, PGS-100, POM-01, EFM-100.
8BMSGlobal TSP-70005/25/201105:19:0005/26/201112:16:00Due to a planned power outage for SRRL construction activities, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, TSI-880, PGS-100, POM-01, EFM-100.
9BMSGlobal TSP-70005/17/201114:20:0005/17/201114:48:00Due to a planned power outage for SRRL construction activities, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, TSI-880, PGS-100, POM-01, EFM-100.
10BMSGlobal TSP-70005/07/201105:18:0005/07/201111:45:00Due to a planned power outage for SRRL construction activities, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, TSI-880, PGS-100, POM-01, EFM-100.
11BMS0212-2Global TSP-70004/17/201112:00:00There is an occasional drastic noise or signal drop out problem with the SRRL BMS TSP-700 during this time. The instrument connections will be re-seated the next time a problem occurs.
12BMSGlobal TSP-70004/15/201106:11:0004/15/201106:50:00Due to a planned power outage for SRRL construction activities, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210W, SPN1, TSI-880, PGS-100, POM-01, EFM-100.
13BMS0212-2Global TSP-70010/04/201013:00:0010/06/201008:00:00There is an occasional drastic noise or signal drop out problem with the SRRL BMS TSP-700 during this time. The connector at the J-box was re-seated.
14BMS0212-2Global TSP-70009/22/201012:00:0010/04/201008:00:00There is an occasional drastic noise or signal drop out problem with the SRRL BMS TSP-700 during this time. All screws in TSP-700 power supply box were retightened.
15BMS0212-2Global TSP-70008/11/201000:00:0008/29/201019:00:00There is an occasional drastic noise or signal drop out problem with the SRRL BMS TSP-700 during this time. Problem appears to have stopped on 8/29/2010.
16BMS0212-2Global TSP-70012/13/200900:00:0012/17/200915:30:00There is an occasional drastic noise or signal drop out problem with the SRRL BMS TSP-700 during this time. Some days there is no problem. (4) screws in the patch panel for this channel were retightened which seemed to fix the problem.
17BMS0212-2Global TSP-70012/09/200910:52:0012/09/200914:22:00Due to a power outage (and bad power) at NREL, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210, SPN1, Snow Depth, TSI-880, POM-01.
18BMS0212-2Global TSP-70007/14/200900:00:0011/11/200912:30:00There is an occasional drastic noise or signal drop out problem with the SRRL BMS TSP-700 during this time. Some days there is no problem. Several screws in the power supply box were retightened which seemed to fix the problem.
19BMS0212-2Global TSP-70011/15/200807:45:0011/15/200814:29:00Due to a planned power outage at SRRL, the following BMS instruments were down: TSP-1, TSP-700, UVSAT, UVSBT, CUVA1, CUVA2, CUVB1, CUVB2, UVB-1, 501A, MS210, SPN1, Snow Depth, TSI-880, SkyCam.
20BMS0212-2Global TSP-70009/26/200800:00:0003/04/200914:00:00There is an occasional drastic noise problem with the SRRL BMS TSP-700, which started showing up 9/26/2008. Every screw between the data logger and instrument was retightened, this includes the patch panel and power supply box, which seemed to solve the problem.
21BMS0212-2Global TSP-70005/29/200800:00:0006/09/200813:00:00The signal from the TSP-700 would occasionally drop low during this time frame. A screw was tightened in the power supply box, which seemed to fix the problem.
22BMS0212-2Global TSP-70012/22/200708:41:0012/22/200711:24:00Due to a scheduled SRRL/Mesa Top power outage on 12/22/2007, the TSP-1, TSP-700, All Global UVA and UVB, and the TWC Photometer were without power, therefore data is either bad or bogus.
23BMS0212-2Global TSP-70005/25/200610:50:0005/25/200611:10:00Data from the Yankee instrument is bad or bogus due to power shutdown for installation of new SRRL equipment lift.
24BMS0212-2Global TSP-70011/18/200508:20:0011/18/200512:06:00The SRRL BMS Yankee TSP-700 was down for power supply upgrade. The old Condor HAA15-0.8-A+ (+/-12 V @ 1 Amp) was replaced with a new Condor HB12-1.7-A+ (+12 V @ 1.7 Amp). The new higher current power supply can now restart the TSP-700 after a power failure. Note: The -12 V output on the old power supply was not needed (Yankee had designed it as a universal power supply for all their instruments).
25BMS0212-2Global TSP-70011/04/200523:14:0011/09/200508:42:00The SRRL BMS Yankee TSP-700 has been down due to a design flaw or fault with the Yankee power supply, caused by a power outage on 11/4/2005 at 23:14 MST. The power supply is unable to power up both the ventilator and the heater simultaneously (even though it was designed to). Data during this time is bogus.