| R# | Site | Serial Number | Measurement | Start Date | Start Time | End Date | End Time | Data Quality Statement |
| 1 | SRRL BMS | | Downwelling PIR | 03/02/2013 | 13:06:00 | 03/02/2013 | 18:24:00 | Due to a scheduled NREL power outage, to upgrade campus power capacity, The following BMS instruments were not pointing at the sun during this time: Direct CH1, NIP #2, NIP #1, LI-201, NIP RG780, CUVA2, CUVB2, TWC; and the following instruments were un-shaded: Diffuse 8-48, PSP, CM22, CUV4, PIR, CG4. The Sci-Tec tracker for these insruments are protected by UPS, however the battery depleted at 13:06 MST (the power outage started at 8:06 MST) |
| 2 | SRRL BMS | | Downwelling PIR | 05/07/2011 | 05:55:00 | 05/09/2011 | 07:58:00 | There was a planned power outage for SRRL construction activities that started at 5:18 MST. Unfortunately, the backup generator provided to SRRL was providing bad power to the UPS powering the Sci-Tec trackers, therefore the UPS failed at 5:55 MST. Unfortunately, when normal AC power was restored at 11:45 MST, the Sci-Tec trackers had lost all their configuration due to UPS cycling on and off during the outage, therefore were not tracking. The tracker settings were restored on May 9 at 7:58 MST. The following BMS instruments were not pointing at the sun during this time: Direct CH1, NIP #2, NIP #1, LI-201, NIP RG780, CUVA2, CUVB2, TWC; and the following instruments were un-shaded: Diffuse 8-48, PSP, CM22, CUV4, PIR, CG4 |
| 3 | SRRL BMS | | Downwelling PIR | 05/27/2010 | 18:00:00 | 05/28/2010 | 12:15:00 | Due to improper mounting of the replacement CH1 s/n 080033 the Sci-tec tracker was not tracking properly due to collision with the CH1 against tracker. The following BMS instruments were not pointing at the sun: Direct CH1, NIP2, CUVA2, & CUVB2 and the following instruments were unshaded: 8-48, PSP, PIR. |
| 4 | SRRL BMS | | Downwelling PIR | 12/09/2009 | 12:11:00 | 12/09/2009 | 14:22:00 | Due to a power outage at NREL, followed by bad power, the SRRL tracker UPS shutdown. The following BMS instruments were not pointing at the sun: Direct CH1, NIP1, NIP2, NIP-RG780, LI201, TWC500, CUV4; and the following instruments were unshaded: 8-48, CM22, PSP, CUV4, PIR, CG4. |
| 5 | SRRL BMS | | Downwelling PIR | 11/15/2008 | 14:02:00 | 11/15/2008 | 14:32:00 | Due to a planned power outage at SRRL, the following BMS instruments were unshaded: Diffuse 8-48, CM22, PSP, CUV4, DW-PIR, DW-CG4. |
| 6 | SRRL BMS | 31194F3 | Downwelling PIR | 05/25/2006 | 10:50:00 | 05/25/2006 | 11:10:00 | Sci-Tec tracker #1 tracker was down due to power shutdown for installation of new SRRL equipment lift. The following instruments were UNSHADED: Diffuse 8-48, Diffuse PSP, and the Downwelling PIR. |
| 7 | SRRL BMS | 31194F3 | Downwelling PIR | 01/11/2006 | 14:16:00 | 01/31/2006 | 23:59:00 | The K0 factor was mistakenly entered as -4.8 (instead of the correct -4.58) in the datalogger program. This creates a very minor 0.22 W/m^2 bias in the irradiance levels. |
| 8 | SRRL BMS | 31192F3 | Downwelling PIR | 07/23/2005 | 10:16:00 | 07/23/2005 | 17:22:00 | Sci-Tec tracker #1 was down due to a scheduled NREL power outage on 7/23/2005 at 5:33 MST. The following instruments were UNSHADED: Diffuse 8-48, Diffuse PSP, and the Downwelling PIR. |
| 9 | SRRL BMS | 31192F3 | Downwelling PIR | 07/10/2005 | 09:30:00 | 07/10/2005 | 23:59:00 | The SRRL BMS Sci-Tec Tracker #1 was hung up on cables during this time. The following instruments were UNSHADED: Diffuse 8-48, Diffuse PSP and the PIR. |
| 10 | SRRL BMS | | Downwelling PIR | 10/30/2003 | 04:00:00 | 11/07/2003 | 21:00:00 | A problem with the instrument cable was causing the PIR Case Temperature to read approx. 2°C high, which caused the downwelling infrared to read about 50 W/m² high. The downwelling IR is also used for calculating the following: Net Radiation (Eppley), Net Infrared PIR (atmos), and the Diffuse PSP (vent/thermal corrected). |
| 11 | SRRL BMS | | Downwelling PIR | 01/14/1999 | 11:15:00 | 01/20/1999 | 10:50:00 | Downwelling and Upwelling Infrared (PIRs) were not operating correctly during this time frame, this data cannot be fixed. |