| R# | Site | Serial Number | Measurement | Start Date | Start Time | End Date | End Time | Data Quality Statement |
| 1 | SRRL BMS | | Direct NIP RG780 | 03/08/2013 | 08:00:00 | 03/11/2013 | 07:55:00 | The RG780 filter was not covering the NIP during this time. Most likely left open during a cleaning event. |
| 2 | SRRL BMS | | Direct NIP RG780 | 03/02/2013 | 13:06:00 | 03/02/2013 | 18:24:00 | Due to a scheduled NREL power outage, to upgrade campus power capacity, The following BMS instruments were not pointing at the sun during this time: Direct CH1, NIP #2, NIP #1, LI-201, NIP RG780, CUVA2, CUVB2, TWC; and the following instruments were un-shaded: Diffuse 8-48, PSP, CM22, CUV4, PIR, CG4. The Sci-Tec tracker for these insruments are protected by UPS, however the battery depleted at 13:06 MST (the power outage started at 8:06 MST) |
| 3 | SRRL BMS | | Direct NIP RG780 | 05/26/2012 | 06:15:00 | 05/26/2012 | 07:12:00 | Due to a planned power outage for SRRL electrical work, the following BMS instruments were not following the sun: NIP #1, RG780 NIP, LI-201, TWC Photometer and the following instruments were not shaded CM22, CUV4, and CG4. |
| 4 | SRRL BMS | 17837E6 | Direct NIP RG780 | 10/14/2011 | 08:37:00 | 10/17/2011 | 08:46:00 | The RG780 filter was not covering the NIP during this time. Most likely left open during a cleaning event. |
| 5 | SRRL BMS | | Direct NIP RG780 | 09/08/2011 | 08:23:00 | 09/08/2011 | 09:38:00 | Due to a planned power outage for SRRL construction activities, the following BMS instruments were not following the sun: NIP #1, RG780 NIP, LI-201, TWC Photometer and the following instruments were not shaded CM22, CUV4, and CG4. |
| 6 | SRRL BMS | | Direct NIP RG780 | 05/07/2011 | 05:55:00 | 05/09/2011 | 07:58:00 | There was a planned power outage for SRRL construction activities that started at 5:18 MST. Unfortunately, the backup generator provided to SRRL was providing bad power to the UPS powering the Sci-Tec trackers, therefore the UPS failed at 5:55 MST. Unfortunately, when normal AC power was restored at 11:45 MST, the Sci-Tec trackers had lost all their configuration due to UPS cycling on and off during the outage, therefore were not tracking. The tracker settings were restored on May 9 at 7:58 MST. The following BMS instruments were not pointing at the sun during this time: Direct CH1, NIP #2, NIP #1, LI-201, NIP RG780, CUVA2, CUVB2, TWC; and the following instruments were un-shaded: Diffuse 8-48, PSP, CM22, CUV4, PIR, CG4 |
| 7 | SRRL BMS | | Direct NIP RG780 | 04/15/2011 | 06:43:00 | 04/15/2011 | 06:50:00 | There was a planned power outage for SRRL construction activities that started at 6:11 MST. Unfortunately, the UPS powering the Sci-Tec trackers failed due to bad/old batteries at 6:43 MST. The following BMS instruments were not point at the sun for this brief period of time: CH1, NIP #2, NIP #1, LI-201, NIP RG780. |
| 8 | SRRL BMS | | Direct NIP RG780 | 03/18/2011 | 00:00:00 | 03/18/2011 | 07:57:00 | The Sci-Tec #2 tracker was jammed on the shading plate. The following instruments were unshaded: CM22, CUV4, CG4; and the following instruments were not pointing at the sun: NIP #1, NIP RG780, LI-201, TWC Photometer. |
| 9 | SRRL BMS | 31355E6 | Direct NIP RG780 | 10/30/2010 | 00:00:00 | 11/01/2010 | 11:27:00 | The Sci-Tec #2 tracker was apparently not working during this time. The following instruments were unshaded: CM22, CUV4, CG4; and the following instruments were not pointing at the sun: NIP #1, NIP RG780, LI-201. |
| 10 | SRRL BMS | 17837E6 | Direct NIP RG780 | 06/10/2010 | 06:20:00 | 06/11/2010 | 07:40:00 | The RG780 filter was not covering the NIP during this time. Most likely left open during a cleaning event. |
| 11 | SRRL BMS | | Direct NIP RG780 | 12/15/2009 | 09:40:00 | 12/15/2009 | 10:00:00 | The Sci-Tec #2 tracker collided with another empty Sci-Tec tracker. The following instruments were unshaded: CM22, CUV4, CG4; and the following instruments were not pointing at the sun: NIP #1, NIP RG780, LI-201. |
| 12 | SRRL BMS | 17837E6 | Direct NIP RG780 | 07/30/2009 | 12:45:00 | 07/30/2009 | 23:59:00 | The Sci-Tec #2 tracker was apparently not working during this time. The following instruments were unshaded: CM22, CUV4, CG4; and the following instruments were not pointing at the sun: NIP #1, NIP RG780, LI-201. |
| 13 | SRRL BMS | 17837E6 | Direct NIP RG780 | 05/25/2006 | 10:50:00 | 05/25/2006 | 11:26:00 | Sun Follower III tracker was down due to power shutdown for installation of new SRRL equipment lift. The following instruments were NOT pointing at the SUN: NIP #1, NIP RG780, CUVB2, LI-201, TWC (500nm). |
| 14 | SRRL BMS | 17837E6 | Direct NIP RG780 | 11/17/2005 | 06:51:00 | 11/17/2005 | 08:32:00 | The RG780 filter was not covering the NIP during this time. The Filter Wheel had moved sometime before sunrise to the half open position, most likely caused by a bird sitting on the wheel. |
| 15 | SRRL BMS | 17837E6 | Direct NIP RG780 | 11/05/2005 | 06:37:00 | 11/07/2005 | 08:10:00 | Sun Follower III tracker was down due to a power outage on 11/4/2005 at 23:14 MST. The following instruments were NOT pointing at the SUN: NIP #1, NIP RG780, CUVB2, LI-201. |
| 16 | SRRL BMS | 17837E6 | Direct NIP RG780 | 07/23/2005 | 10:16:00 | 07/24/2005 | 09:01:00 | Sun Follower III tracker was down due to a scheduled NREL power outage on 7/23/2005 at 5:33 MST. The following instruments were NOT pointing at the SUN: NIP #1, NIP RG780, CUVB2, LI-201. |
| 17 | SRRL BMS | 17837E6 | Direct NIP RG780 | 07/16/2005 | 00:00:00 | 07/18/2005 | 07:46:00 | The Sun Follower III tracker was hung up on cables, due to a research NIP removal that occured earlier in the week. This instrument was not pointing at the sun during this time. |
| 18 | SRRL BMS | | Direct RG780 NIP | 05/22/2002 | 06:00:00 | 06/07/2002 | 08:30:00 | The RG780 filter on the NIP was removed to allow the instrument to be calibrated in BORCAL 2002-02. Affected times (MST) were: 5-22-02 6:00 to 5-23-02 9:00, 5-30-02 5:30 to 6-3-02 10:00, 6-5-02 4:30 to 6-7-02 8:30. |