R# | Serial Number | Calibration Facility | Calibration Date | Date for next Calibration | Responsivity [45] | Calibration Factor [45] | Instrument::Make | Instrument::Model | Instrument::Description | Instrument::Program | Instrument::Factory Calibration | Instrument::Date of Factory Calibration | Responsivity Bins [2 deg] | Responsivity Function Coefficients | Other Calibrations | Calibration File | Contact Person | Documentation Title | Calibration Method | Calibration Notes | Other Information | Datalogger Entry Date | Responsivity [45] [Corr] | Calibration Factor [45] [Corr] | Correction Method | Responsivity Bins Average [2 deg] |
1 | S09032 | NREL/Optics Lab | 02/26/2010 | 08/26/2010 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2010_02.rpt.zip][100_2010_02.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-158 w/Direct Tube | cal files and report online; factory loaner; irradiance calibration only | OUT of Tolerance; calibrated using S08029 wavelength | 01/29/2010 | | | | |
2 | S09032 | NREL/Optics Lab | 08/20/2010 | 02/20/2011 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2010_08.rpt.zip][100_2010_08.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-158 w/Direct Tube | cal files and report online | IN Tolerance | 09/03/2010 | | | | |
3 | S09032 | NREL/Optics Lab | 03/01/2011 | 09/01/2011 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2011_03.rpt.zip][100_2011_03.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-158 w/Direct Tube | cal files and report online | IN Tolerance | 03/01/2011 | | | | |
4 | S09032 | NREL/Optics Lab | 02/27/2012 | 08/27/2012 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2012_02.rpt.zip][100_2012_02.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-158 w/Direct Tube | cal files and report online | IN Tolerance | 02/27/2012 | | | | |
5 | S09032 | NREL/Optics Lab | 09/28/2012 | 03/28/2013 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2012_09.rpt.zip][100_2012_09.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-102 w/Direct Tube | cal files and report online | IN Tolerance | 10/01/2012 | | | | |
6 | S09032 | NREL/Optics Lab | 04/26/2013 | 10/26/2013 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2013_04.rpt.zip][100_2013_04.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-102 w/Direct Tube on Brusag | cal files and report online | IN Tolerance | 05/14/2013 | | | | |
7 | S09032 | NREL/Optics Lab | 12/12/2013 | 06/12/2014 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2013_12.rpt.zip][100_2013_12.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-102 w/Direct Tube on Brusag | cal files and report online | IN Tolerance | 12/12/2013 | | | | |
8 | S09032 | NREL/Optics Lab | 11/06/2014 | 05/06/2015 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2014_11.rpt.zip][100_2014_11.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-102 w/Direct Tube on Brusag | cal files and report online | IN Tolerance | 11/07/2014 | | | | |
9 | S09032 | NREL/Optics Lab | 03/10/2016 | 03/10/2017 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2016_03.rpt.zip][100_2016_03.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-175 w/Direct Tube on Brusag | cal files and report online | IN Tolerance | 03/17/2016 | | | | |
10 | S09032 | NREL/Optics Lab | 05/12/2017 | 05/12/2018 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2017_05.rpt.zip][100_2017_05.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-175 w/Direct Tube on Brusag | cal files and report online | IN Tolerance | 05/20/2017 | | | | |
11 | S09032 | NREL/Optics Lab | 05/08/2018 | 05/08/2020 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2018_05.rpt.zip][100_2017_05.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs LI-1800 PRS-175 w/Direct Tube on Brusag | cal files and report online | IN Tolerance; no calibration adjustment | 05/20/2017 | | | | |
12 | S09032 | NREL/Optics Lab | 05/22/2020 | 05/22/2022 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2020_05.rpt.zip][100_2020_05.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs S-9011 w/Direct Tube on EKO | cal files and report online | | 05/26/2020 | | | | |
13 | S09032 | NREL/Optics Lab | 08/30/2022 | 08/30/2024 | | | PREDE | PGS-100 | Direct Normal Spectroradiometer | NREL/Program | | | | | [100_2022_08.rpt.zip][100_2022_08.cal.zip] | | Afshin Andreas | PGS-100 Calibration Report | Outdoors vs S-9011 w/Direct Tube on EKO | cal files and report online | | 09/23/2022 | | | | |