R# | Site | Serial Number | Measurement | Start Date | Start Time | End Date | End Time | Data Quality Statement |
26 | BMS | | Global Normal SP Lite | 03/17/2021 | 17:32:00 | 03/19/2021 | 16:14:00 | For an experiment, the 1-axis and 2-axis trackers were placed in a 40-degree South Fixed Tilt, this affects the following instruments: Global Normal CMP22, SP-Lite2, LI-200R, WISER; Global 1-Axis CMP22, SP-Lite2, LI-200R, WISER |
27 | BMS | | Global Normal | 11/17/2020 | 07:21:00 | 11/17/2020 | 07:45:00 | Due to a scheduled NREL/SRRL power outage, to replace a surge protection device on the SRRL building, The following BMS instruments were not tracking the sun during this time: Global Normal CMP22, SP-Lite2, LI-200R; Global 1-Axis CMP22, SP-Lite2, LI-200R |
28 | BMS | | Global Normal LI-200R | 11/17/2020 | 07:21:00 | 11/17/2020 | 07:45:00 | Due to a scheduled NREL/SRRL power outage, to replace a surge protection device on the SRRL building, The following BMS instruments were not tracking the sun during this time: Global Normal CMP22, SP-Lite2, LI-200R; Global 1-Axis CMP22, SP-Lite2, LI-200R |
29 | BMS | | Global Normal SP Lite | 11/17/2020 | 07:21:00 | 11/17/2020 | 07:45:00 | Due to a scheduled NREL/SRRL power outage, to replace a surge protection device on the SRRL building, The following BMS instruments were not tracking the sun during this time: Global Normal CMP22, SP-Lite2, LI-200R; Global 1-Axis CMP22, SP-Lite2, LI-200R |
30 | BMS | | Global Normal | 06/19/2020 | 12:14:00 | 12/15/2021 | 19:31:00 | DATA CORRECTED on 12/17/2021: Irradiances were increased by 0.675% due to revised BORCAL report for all BMS shortwave radiometers calibrated in 2020 and 2021. |
31 | BMS | | Global Normal LI-200R | 06/19/2020 | 12:14:00 | 12/15/2021 | 19:31:00 | DATA CORRECTED on 12/17/2021: Irradiances were increased by 0.675% due to revised BORCAL report for all BMS shortwave radiometers calibrated in 2020 and 2021. |
32 | BMS | | Global Normal SP Lite | 06/19/2020 | 12:14:00 | 12/15/2021 | 19:31:00 | DATA CORRECTED on 12/17/2021: Irradiances were increased by 0.675% due to revised BORCAL report for all BMS shortwave radiometers calibrated in 2020 and 2021. |
33 | BMS | | Global Normal | 07/28/2018 | 00:00:00 | 07/30/2018 | 09:30:00 | The global normal tracker was not working during this time, data for the Global Normal CMP11 and LI-200R should not be used. Problem Unknown. |
34 | BMS | | Global Normal LI-200R | 07/28/2018 | 00:00:00 | 07/30/2018 | 09:30:00 | The global normal tracker was not working during this time, data for the Global Normal CMP11 and LI-200R should not be used. Problem Unknown. |
35 | BMS | | Global Normal | 07/22/2018 | 00:00:00 | 07/23/2018 | 08:45:00 | The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used. Power cable had come unplugged to AC adapter. AC adapter was relocated to prevent future unplugging.
|
36 | BMS | | Global Normal LI-200R | 07/22/2018 | 00:00:00 | 07/23/2018 | 08:45:00 | The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used. Power cable had come unplugged to AC adapter. AC adapter was relocated to prevent future unplugging.
|
37 | BMS | PY100362 | Global Normal LI-200R | 05/08/2017 | 13:30:00 | 05/11/2017 | 10:50:00 | Instrument is reading bogus after heavy hail storm at SRRL. It appears that the signal cable inside the bendix connector was broken. The sensor was replaced with the calibration spare (S/N PY100361) until it can be repaired. |
38 | BMS | | Global Normal LI-200R | 02/21/2017 | 00:00:00 | 02/22/2017 | 09:15:00 | The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used. Corroded connector was found at battery, replaced connector which restored 18 VDC to tracker.
|
39 | BMS | | Global Normal | 02/21/2017 | 00:00:00 | 02/22/2017 | 09:15:00 | The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used. Corroded connector was found at battery, replaced connector which restored 18 VDC to tracker.
|
40 | BMS | | Global Normal | 02/17/2017 | 00:00:00 | 02/17/2017 | 13:00:00 | The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used.
|
41 | BMS | | Global Normal LI-200R | 02/17/2017 | 00:00:00 | 02/17/2017 | 13:00:00 | The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used.
|
42 | BMS | | Global Normal LI-200R | 02/04/2017 | 00:00:00 | 02/06/2017 | 09:00:00 | The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used.
|
43 | BMS | | Global Normal | 02/04/2017 | 00:00:00 | 02/06/2017 | 09:00:00 | The global normal tracker was not working during this time (pointed toward ground), data for the Global Normal CMP11 and LI-200R should not be used.
|
44 | BMS | | Global Normal LI-200R | 01/06/2017 | 00:00:00 | 01/17/2017 | 13:50:00 | The global normal tracker has been having occasional tracking problems on various days during this time frame, data for the Global Normal CMP11 and LI-200R may be affected.
|
45 | BMS | | Global Normal | 01/06/2017 | 00:00:00 | 01/17/2017 | 13:50:00 | The global normal tracker has been having occasional tracking problems on various days during this time frame, data for the Global Normal CMP11 and LI-200R may be affected.
|
46 | BMS | | Global Normal LI-200R | 12/01/2016 | 13:00:00 | 12/05/2016 | 12:26:00 | When the LI-200R was first installed the data logger output was accidentally set to sample instead of average during this time, so data was 1-minute samples instead of 1-minute averages, as a result data will disagree with other instruments during cloud passage. |
47 | BMS | | Global Normal LI-200R | 12/01/2016 | 13:00:00 | 12/14/2016 | 08:44:00 | When the LI-200R was first installed the calibration factor at 45 degrees was used instead of the preferred 0 degrees for global normal:CF@45=91.575 W/mē/mV; CF@0=91.707 W/mē/mV.
|
48 | BMS | 140840 | Global Normal | 07/04/2016 | 00:00:00 | 07/05/2016 | 14:00:00 | The LICOR LI-2020 tracker is not working during this time, data should not be used during this time. |
49 | BMS | 140840 | Global Normal | 01/17/2016 | 00:00:00 | 01/18/2016 | 15:30:00 | The LICOR LI-2020 tracker is not working during this time, data should not be used during this time. |
50 | BMS | 140840 | Global Normal | 09/21/2015 | 00:00:00 | 09/21/2015 | 14:20:00 | The LICOR LI-2020 tracker is not working during this time, instrument is facing northward/downward. |