Skip to content National Residential Efficiency Measures Database National Renewable Energy Laboratory

Submit Questions/Comments

Retrofit Measures for Furnace

Here you will find the data for Furnace measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Furnace measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Furnace measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Access
  • Condition of existing flue
  • Need to bring in combustion air
  • Condition of existing electrical system
  • Need for additional wiring/switching
  • Condition of existing gas line
  • Presence of hazardous materials
  • Stand alone vs treating both heating/cooling
  • Need for controls and/or zoning
  • Condition of existing duct system
  • Type of equipment

Viewing 502 Furnace Measure(s) of 502

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1000 - 17001400

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 540 - 1200900

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 60% AFUE

Properties:

  • AFUE: 0.6 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 64% AFUE

Properties:

  • AFUE: 0.64 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 68% AFUE

Properties:

  • AFUE: 0.68 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 72% AFUE

Properties:

  • AFUE: 0.72 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 76% AFUE

Properties:

  • AFUE: 0.76 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 10 - 2115
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 82% AFUE

Properties:

  • AFUE: 0.82 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • AFUE: 0.98 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 17 - 3424
$ 680 - 15001100

Remove Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

None

Properties:

  • AFUE: Btu/Btu
  • Fuel Type:
  • Max Supply Temp: degrees F
 

Measure Cost

UnitsRangeAverage
$ 140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.3 - 128.7
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • AFUE: 0.85 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 14 - 2719
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 19 - 3726
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 24 - 4734
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 21 - 4129
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 23 - 4532
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 92% AFUE

Properties:

  • AFUE: 0.92 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • AFUE: 0.96 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 25 - 4935
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • AFUE: 1.0 Btu/Btu
  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 36 - 7150
$ 1200 - 20001600

Replace Furnace:

Before-Component After-Component Cost

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • AFUE: 0.78 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 6.4 - 139
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • AFUE: 0.8 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 8.4 - 1612
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • AFUE: 0.9 Btu/Btu
  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Energy Star 2006
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh 15 - 2920
$ 680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Propane, 94% AFUE

Properties:

  • AFUE: 0.94 Btu/Btu
  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006
  • Exceeds Federal Standard