Here you will find the data for Unfinished Basement measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Unfinished Basement measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Unfinished Basement measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Access
  • Presence/condition/type of existing insulation
  • Existing construction and materials
  • Moisture issues present
  • Presence of hazardous materials
  • Extent of preparation
  • Accommodation for termite inspections

Viewing 16 Unfinished Basement Measure(s) of 16

Insulate Unfinished Basement Ceiling with Fiberglass Batt:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Ceiling R-13 Fiberglass Batt

Properties:

  • Ceiling Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Performance Standards:

  • Meets IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Ceiling 0.58 - 1.10.85

Insulate Unfinished Basement Ceiling with Fiberglass Batt:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Ceiling R-19 Fiberglass Batt

Properties:

  • Ceiling Cavity Insulation Nominal R-value: 19.0 h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2009 (3A, 3B, 3C, 4A, 4B)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (3A, 3B, 3C, 4A, 4B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Ceiling 0.67 - 1.20.96

Insulate Unfinished Basement Ceiling with Fiberglass Batt:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Ceiling R-30 Fiberglass Batt

Properties:

  • Ceiling Cavity Insulation Nominal R-value: 30.0 h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B)
  • Meets IECC 2009 (4C, 5A, 5B, 5C, 6A, 6B, 6C)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Ceiling 0.82 - 1.51.2

Insulate Unfinished Basement Ceiling with Fiberglass Batt:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Ceiling R-38 Fiberglass Batt

Properties:

  • Ceiling Cavity Insulation Nominal R-value: 38.0 h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C)
  • Meets IECC 2009 (7, 8)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C)
  • Meets IECC 2012 (7, 8)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Ceiling 0.94 - 1.71.3

Insulate Unfinished Basement Wall with Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Half Wall R-12 Polyiso

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type: fasteners
  • Wall Continuous Insulation Nominal R-value: 12.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 2.0 in
  • Wall Continuous Insulation Type: polyiso
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: frac
  • Wall Insulation Height: 4.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 1.7 - 2.82.2

Insulate Unfinished Basement Wall with Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Half Wall R-6 Polyiso

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type: fasteners
  • Wall Continuous Insulation Nominal R-value: 6.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 1.0 in
  • Wall Continuous Insulation Type: polyiso
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: frac
  • Wall Insulation Height: 4.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 1.6 - 2.62.1

Insulate Unfinished Basement Wall with Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-10 XPS

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type: furring strips
  • Wall Continuous Insulation Nominal R-value: 10.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 2.0 in
  • Wall Continuous Insulation Type: xps
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.25 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 2.2 - 3.72.9

Insulate Unfinished Basement Wall with Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-12 Polyiso

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type: furring strips
  • Wall Continuous Insulation Nominal R-value: 12.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 2.0 in
  • Wall Continuous Insulation Type: polyiso
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.25 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 2 - 3.42.7

Insulate Unfinished Basement Wall with Fiberglass Batt:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-13 Fiberglass Batt

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Wall Cavity Insulation Type: fiberglass batt
  • Wall Construction Type: frame wall
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.25 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 2.3 - 4.13.2

Insulate Unfinished Basement Wall with Fiberglass Batt and Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-13 Fiberglass Batt, R-10 XPS

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Wall Cavity Insulation Type: fiberglass batt
  • Wall Construction Type: frame wall
  • Wall Continuous Insulation Nominal R-value: 10.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 2.0 in
  • Wall Continuous Insulation Type: xps
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.25 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 3.7 - 6.24.9

Insulate Unfinished Basement Wall with Fiberglass Batt and Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-13 Fiberglass Batt, R-5 XPS

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Wall Cavity Insulation Type: fiberglass batt
  • Wall Construction Type: frame wall
  • Wall Continuous Insulation Nominal R-value: 5.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 1.0 in
  • Wall Continuous Insulation Type: xps
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.25 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 3.3 - 5.64.4

Insulate Unfinished Basement Wall with Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-15 XPS

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type: furring strips
  • Wall Continuous Insulation Nominal R-value: 15.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 3.0 in
  • Wall Continuous Insulation Type: xps
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.25 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 2.6 - 4.33.4

Insulate Unfinished Basement Wall with Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-18 Polyiso

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type: furring strips
  • Wall Continuous Insulation Nominal R-value: 18.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 3.0 in
  • Wall Continuous Insulation Type: polyiso
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.25 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 2.3 - 3.83

Insulate Unfinished Basement Wall with Fiberglass Batt:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-19 Fiberglass Batt

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: 19.0 h-ft^2-R/Btu
  • Wall Cavity Insulation Type: fiberglass batt
  • Wall Construction Type: frame wall
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.22 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 2.7 - 4.83.7

Insulate Unfinished Basement Wall with Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-5 XPS

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type: furring strips
  • Wall Continuous Insulation Nominal R-value: 5.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 1.0 in
  • Wall Continuous Insulation Type: xps
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.25 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 1.8 - 32.4

Insulate Unfinished Basement Wall with Rigid Foam Board:

Before-Component After-Component Cost

Uninsulated

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type:
  • Wall Continuous Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: in
  • Wall Continuous Insulation Type:
  • Wall Finish Material:
  • Wall Framing Factor: frac
  • Wall Insulation Height: ft

Lifetime:

  • 999 Years
 

Whole Wall R-6 Polyiso

Properties:

  • Ceiling Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Wall Cavity Insulation Type:
  • Wall Construction Type: furring strips
  • Wall Continuous Insulation Nominal R-value: 6.0 h-ft^2-R/Btu
  • Wall Continuous Insulation Thickness: 1.0 in
  • Wall Continuous Insulation Type: polyiso
  • Wall Finish Material: 1/2" gypsum
  • Wall Framing Factor: 0.25 frac
  • Wall Insulation Height: 8.0 ft

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Basement Wall 1.8 - 2.92.3

Version: v3.0.0