Skip to content National Residential Efficiency Measures Database National Renewable Energy Laboratory

Submit Questions/Comments

Retrofit Measures for Skylights

Here you will find the data for Skylights measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Skylights measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Skylights measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Roof slope
  • Access
  • Existing construction and materials
  • Moisture issues present
  • Presence of hazardous materials

Viewing 136 Skylights Measure(s) of 136

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4032

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 25 - 4737

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 23 - 4334

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 30 - 5544

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 33 - 6149

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4032

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4031

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 25 - 4737

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 23 - 4334

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 30 - 5544

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 33 - 6149

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4032

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 25 - 4737

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 30 - 5544

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 33 - 6149

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 25 - 4737

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 23 - 4334

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 30 - 5544

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 33 - 6149

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 30 - 5544

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 33 - 6149

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 33 - 6149

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4032

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 25 - 4737

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 23 - 4334

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 30 - 5544

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 33 - 6149

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4032

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4032

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4031

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 25 - 4737

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 23 - 4334

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 30 - 5544

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 33 - 6149

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4032

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 3931

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 3931

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.75
  • U-Value: 1.98 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.1 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4032

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • U-Value: 1.3 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4031

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • U-Value: 0.84 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 25 - 4737

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.62
  • U-Value: 0.95 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 23 - 4334

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.74 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 30 - 5544

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, High-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.52
  • U-Value: 0.68 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 35 - 6452

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame

Properties:

  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • U-Value: 0.7 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 33 - 6149

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.2
  • U-Value: 0.5 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 77 - 130110

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Metal Frame

Properties:

  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.37
  • U-Value: 1.17 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 4032

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.65 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)
  • Exceeds Energy Star 2010 (Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 39 - 7057

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Double-Pane, Low-Gain Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.25
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 59 - 10085

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 21 - 3931

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Single-Pane, Clear, Non-metal Frame

Properties:

  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.64
  • U-Value: 1.47 Btu/h-R-ft^2

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 91 - 160130

Replace:

Before-Component After-Component Cost

Triple-Pane, Medium-Gain, Clear, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: clear
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.47 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Replace:

Before-Component After-Component Cost

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Low-Gain, Low-E, Insulated Frame, Argon Fill

Properties:

  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.2
  • U-Value: 0.3 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 120 - 210170

Replace:

Before-Component After-Component Cost

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Triple-Pane, Medium-Gain, Low-E, Non-metal Frame, Argon Fill

Properties:

  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 3
  • SHGC: 0.3
  • U-Value: 0.35 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010 (North-Central, South-Central, Southern)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Skylight 98 - 170140

Version: v3.0.0