Skip to content National Residential Efficiency Measures Database National Renewable Energy Laboratory

Submit Questions/Comments

Retrofit Measures for Doors (Entry)

Here you will find the data for Doors (Entry) measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Doors (Entry) measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Doors (Entry) measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Existing construction and materials
  • Presence of hazardous materials

Viewing 34 Doors (Entry) Measure(s) of 34

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding Entry, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: fiberglass
  • Operation: sliding
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Sliding Entry, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: fiberglass
  • Operation: sliding
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 460 - 1000770

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding Entry, U-Value: 0.50

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: vinyl
  • Operation: sliding
  • SHGC: 0.53
  • U-Value: 0.5 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding Entry, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: fiberglass
  • Operation: sliding
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 460 - 1000770

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding Entry, U-Value: 0.50

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: vinyl
  • Operation: sliding
  • SHGC: 0.53
  • U-Value: 0.5 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding Entry, U-Value: 0.50

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: vinyl
  • Operation: sliding
  • SHGC: 0.53
  • U-Value: 0.5 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 410 - 880680

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding Entry, U-Value: 1.08

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: wood
  • Operation: sliding
  • SHGC: 0.86
  • U-Value: 1.08 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding Entry, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: fiberglass
  • Operation: sliding
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 460 - 1000770

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding Entry, U-Value: 1.08

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: wood
  • Operation: sliding
  • SHGC: 0.86
  • U-Value: 1.08 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding Entry, U-Value: 0.50

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: vinyl
  • Operation: sliding
  • SHGC: 0.53
  • U-Value: 0.5 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 410 - 880680

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding Entry, U-Value: 1.08

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: wood
  • Operation: sliding
  • SHGC: 0.86
  • U-Value: 1.08 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding Entry, U-Value: 1.08

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: wood
  • Operation: sliding
  • SHGC: 0.86
  • U-Value: 1.08 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 360 - 770600

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.26

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.26

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 240 - 530400

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.26

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Fiberglass Frame, U-Value: 0.21

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.21 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 170 - 360280

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.41

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.26

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 240 - 530400

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.41

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.41

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 230 - 510390

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.41

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Swinging Entry, >1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 250 - 530410

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.41

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Fiberglass Frame, U-Value: 0.21

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.21 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 170 - 360280

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Steel Frame, U-Value: 0.66

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.26

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 240 - 530400

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Steel Frame, U-Value: 0.66

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.41

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 230 - 510390

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Steel Frame, U-Value: 0.66

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Steel Frame, U-Value: 0.66

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 160 - 360270

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Steel Frame, U-Value: 0.66

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Swinging Entry, >1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 250 - 530410

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Steel Frame, U-Value: 0.66

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Fiberglass Frame, U-Value: 0.21

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.21 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 170 - 360280

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, <=1/2-Lite Glazing, Steel Frame, U-Value: 0.66

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Steel Frame, U-Value: 0.55

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 120 - 250190

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.26

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 240 - 530400

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Swinging Entry, >1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 250 - 530410

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Fiberglass Frame, U-Value: 0.21

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.21 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 170 - 360280

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Steel Frame, U-Value: 1.21

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.26

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 240 - 530400

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Steel Frame, U-Value: 1.21

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.41

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 230 - 510390

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Steel Frame, U-Value: 1.21

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Steel Frame, U-Value: 0.66

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 160 - 360270

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Steel Frame, U-Value: 1.21

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Swinging Entry, >1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 250 - 530410

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Steel Frame, U-Value: 1.21

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Swinging Entry, >1/2-Lite Glazing, Steel Frame, U-Value: 1.21

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 230 - 510390

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Steel Frame, U-Value: 1.21

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Fiberglass Frame, U-Value: 0.21

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.21 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 170 - 360280

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, >1/2-Lite Glazing, Steel Frame, U-Value: 1.21

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Steel Frame, U-Value: 0.55

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 120 - 250190

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, Opaque, Fiberglass Frame, U-Value: 0.21

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.21 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Fiberglass Frame, U-Value: 0.21

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.21 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 170 - 360280

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, Opaque, Steel Frame, U-Value: 0.55

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.26

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 240 - 530400

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, Opaque, Steel Frame, U-Value: 0.55

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)

Lifetime:

  • 30 Years
 

Swinging Entry, <=1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.41

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 230 - 510390

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, Opaque, Steel Frame, U-Value: 0.55

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)

Lifetime:

  • 30 Years
 

Swinging Entry, >1/2-Lite Glazing, Fiberglass Frame, U-Value: 0.32

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Meets IECC 2012 (4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 250 - 530410

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, Opaque, Steel Frame, U-Value: 0.55

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Fiberglass Frame, U-Value: 0.21

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.21 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)
  • Exceeds IECC 2012 (2A, 2B, 2C, 3A, 3B, 3C, 4A, 4B, 4C, 5A, 5B, 5C, 6A, 6B, 6C, 7, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 170 - 360280

Replace Swinging Entry Door:

Before-Component After-Component Cost

Swinging Entry, Opaque, Steel Frame, U-Value: 0.55

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)

Lifetime:

  • 30 Years
 

Swinging Entry, Opaque, Steel Frame, U-Value: 0.55

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.55 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C, 2A, 2B, 2C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$ 120 - 250190

Version: v3.0.0